Remove and Install the IP54 Roof Vent Fan Fuse for Frames 8...15
Replace the roof vent fan fuse on a power bay with kit catalog number SK-RM-INVFAN1-FUSE (Time Delay, 250V, 3.5 A, Cartridge). Follow these steps to remove and install the IP54 roof vent fan fuse on a power bay.
- Review the product advisories in Before You Begin.
- Remove power from the system.
- Slide the front vent up to release the tabs from the slots in the vent hood and remove the vent.
- Remove the four M8 x 12 mm Torx screws that secure the screen to the front of the fan housing and remove the screen.
- Unscrew the fuse holder and fuse and remove the fuse.
- Install the IP54 roof vent fan fuse in the reverse order of removal. Tightening torque for the fuse holder is 3.4 N•m (30 lb•in).
Provide Feedback