Size In Elements (SIZE)
The SIZE instruction finds the number of elements (size) in the designated dimension of the
Source array and places the result in the Size operand. The instruction finds the size of
one dimension of an array.
The instruction operates on:
- Arrays
- Arrays in a structure
- Arrays that are part of a larger array
Available Languages
Ladder Diagram
_v1.png/_jcr_content/renditions/original)
FactoryTalk Design Studio
DSL - Ladder DiagramSIZE(Source,Dimtovary,Size);
Structured Text
SIZE(Source,Dimtovary,Size);
Operands
IMPORTANT:
Unexpected operation may occur if:
- Output tag operands are overwritten.
- Members of a structure operand are overwritten.
- Except when specified, structure operands are shared by multiple instructions.
There are data conversion rules for mixing numeric data types within an instruction. See Data conversions.
Ladder Diagram
Operand | Data Type | Format | Description |
|---|---|---|---|
Source | SINT INT DINT REAL structure | Array tag | First element of the array on which the instruction is to operate Tags that are not array are not accepted during verification |
Dimension to Vary | DINT | immediate
(0, 1, 2) | Dimension to use:
|
Size | SINT INT DINT REAL | tag | Tag to store the number of elements in the specified dimension of the array |
See Structured Text syntax for more information on the syntax of
expressions within structured text.
Affects Math Status Flags
No
Major/Minor Faults
None specific to this instruction. See Index through arrays for array-indexing faults.
Execution
Ladder Diagram
Condition/State | Action Taken |
|---|---|
Prescan | N/A |
Rung-condition-in is false | Set Rung-condition-out to Rung-condition-in. |
Rung-condition-in is true | Set Rung-condition-out to Rung-condition-in. The instruction executes. |
Postscan | N/A |
Structured Text
Condition/State | Action Taken |
|---|---|
Prescan | N/A |
Normal execution | Set Rung-condition-out to Rung-condition-in. The instruction executes. |
Postscan | N/A |
Examples
Example 1
Find the number of elements in dimension 0 (first dimension) of array_a. Store the size in array_a_size. In this example, dimension 0 of array_a has 10 elements.
Ladder Diagram

Structured Text
SIZE(array_a,0,array_a_size);