Fiber-optic Interface Circuit Board Status Indicator

The
PowerFlex®
755T fiber-optic interface uses a status indicator to report conditions. The fiber-optic interface circuit board is mounted on the rear panel of the control pod assembly and is used with frame 7…15 drives and bus supplies.
Fiber-optic Interface Status Indicators
The location of status indicators on a fiber-optic interface circuit board.
Fiber-optic Interface Circuit Board Status Indicator - DS1
Color
State
Description
Green
Flashing at 2 Hz
Active mode in process.
Green
Flashing at 0.5 Hz
Update in process
Green/Yellow
Flashing alternately
Login mode in process.
Green/Red
Flashing alternately
Erase in process.
Yellow
Flashing at 2 Hz
Loopback fiber test mode is in process.
Yellow
Flashing at 0.5 Hz
Boot mode is in process.
Red
Blink 2 Count
Clock fault
Red
Blink 3 Count
Firmware fault
Red
Blink 4 Count
FLEXBUS fault
Red
Blink 5 Count
PRGM fault
Red
Blink 6 Count
FPGA PRGM fault
Red
Blink 7 Count
SFLASH PRGM fault