PowerFlex 755TL, 755TR, and 755TM Fan Use

Frames 5...7 Drives
Fan Type
Frame 5 Drives
Frame 6 Drives
Frame 6L Drives
Frame 7 Drives
IP20, NEMA/UL Open Type
IP21, NEMA/UL Type 1
IP54, NEMA/UL Type 12
Control Pod Fan
None
None
None
Single
Single
Stirring Fan
Present
Present
Present
None
None
Heatsink Fan
Present
Present
Present
Present
Present
Input Bay Fan
None
None
None
None
None
Power Bay Roof Fan
None
None
None
Present
Present
Wire Bay Fan
None
None
None
None
None
Control Bay Fan
None
None
None
None
None
Frames 8...15 Drives
Fan Type
Frame 8 Drives
Frame 9 Drives
Frame 10...15 Drives
IP21, NEMA/UL Type 1
IP54, NEMA/UL Type 12
IP21, NEMA/UL Type 1
IP54, NEMA/UL Type 12
IP21, NEMA/UL Type 1
IP54, NEMA/UL Type 12
Control Pod Fan
Dual
Dual
Dual
Dual
Dual
Dual
Stirring Fan
None
None
None
None
None
None
Heatsink Fan
Present
Present
Present
Present
Present
Present
Input Bay Fan
Present
Present
Present
Present
Present
Present
Power Bay Roof Fan
None
Present
None
Present
None
Present
Present (with option)
Present (with option)
Present (with option)
Present (with option)
Present (with option)
Present (with option)
Wire Bay Fan
Present
Present
Present
Present
Present
Present
Control Bay Fan
None
None
None
None
None
None
Frames 8...15 Bus Supplies
Fan Type
Frame 8 Bus Supplies
Frame 9 Bus Supplies
Frame 10...15 Bus Supplies
IP21, NEMA/UL Type 1
IP54, NEMA/UL Type 12
IP21, NEMA/UL Type 1
IP54, NEMA/UL Type 12
IP21, NEMA/UL Type 1
IP54, NEMA/UL Type 12
Control Pod Fan
Dual
Dual
Dual
Dual
Dual
Dual
Stirring Fan
None
None
None
None
None
None
Heatsink Fan
Present
Present
Present
Present
Present
Present
Input Bay Fan
Present
Present
Present
Present
Present
Present
Power Bay Roof Fan
None
Present
None
None
Present
Present
Present (with option)
Present (with option)
Present (with option)
Present (with option)
Present (with option)
Present (with option)
Wire Bay Fan
Present
Present
Present
Present
Present
Present
Control Bay Fan
None
None
None
None
None
None
Frames 8, 9, 10...15 Common Bus Inverters
Fan Type
Frame 8 Common Bus Inverters
Frame 9 Common Bus Inverters
Frame 10...15 Common Bus Inverters
IP21, NEMA/UL Type 1
IP54, NEMA/UL Type 12
IP21, NEMA/UL Type 1
IP54, NEMA/UL Type 12
IP21, NEMA/UL Type 1
IP54, NEMA/UL Type 12
Control Pod Fan
Dual
Dual
Dual
Dual
Dual
Dual
Stirring Fan
None
None
None
None
None
None
Heatsink Fan
Present
Present
Present
Present
Present
Present
Input Bay Fan
None
None
None
None
None
None
Power Bay Roof Fan
None
Present
None
Present
None
Present
Wire Bay Fan
Present (with option)
Present (with option)
Present (with option)
Present (with option)
Present (with option)
Present (with option)
Control Bay Fan
Present (with option)
Present (with option)
Present (with option)
Present (with option)
Present (with option)
Present (with option)
Provide Feedback
Have questions or feedback about this documentation? Please submit your feedback here.