Parameters Not Reset When Set Defaults Most Executes

IMPORTANT: The PowerFlex 20-HIM-A6/-C6S HIM User Manual, publication 20HIM-UM001, provides detailed instructions on using Human Interface Module capabilities, including, setting the
PowerFlex®
750-Series drive to factory settings.

Port 0: Product Config File, Preferences Group

Number
Display Name
Full Name
30
Access Level
User Access Level
31
Language
Display Language
46
Velocity Units
Velocity Units

Port 0: Product Config File, Control Config Group

Number
Display Name
Full Name
33
VoltageClass Cfg
Voltage Class Configure
35
Duty Rating Cfg
Duty Rating Configure

Port 0: Product Config File, Port Mode Group

Number
Display Name
Full Name
65
Pri MtrCtrl Mode
Primary Motor Control Mode
70
Application Sel
Application Select

Port 0: Product Config File, Option Cfg Group

Number
Display Name
Full Name
80
DCP Option
DC Precharge Option
82
TAM Option
Torque Accuracy Module Option

Port 0: Feedback & I/O File, Command Group

Number
Display Name
Full name
134
DI EmergencyOVRD
Digital Input Emergency Override

Port 0: Embedded ENET File, Address Config Group

Number
Display Name
Full Name
300
Net Addr Sel
Network Address Selection
302
IP Addr Cfg 1
IP Address Configuration 1
303
IP Addr Cfg 2
IP Address Configuration 2
304
IP Addr Cfg 3
IP Address Configuration 3
305
IP Addr Cfg 4
IP Address Configuration 4
306
Subnet Cfg 1
Subnet Configuration 1
307
Subnet Cfg 2
Subnet Configuration 2
308
Subnet Cfg 3
Subnet Configuration 3
309
Subnet Cfg 4
Subnet Configuration 4
310
Gateway Cfg 1
Gateway Configuration 1
311
Gateway Cfg 2
Gateway Configuration 2
312
Gateway Cfg 3
Gateway Configuration 3
313
Gateway Cfg 4
Gateway Configuration 4
314
Net Rate Cfg 1
Net Rate Configuration 1
316
Net Rate Cfg 3
Net Rate Configuration 3

Port 0: Protection File, Overrides Group

Number
Display Name
Full Name
454
Emerg OVRD Mode
Emergency Override Mode
455
Emerg Prot OVRD
Protections Overriden by Emergency Override

Parameter 0:457 [Purge Frequency]

ATTENTION:
Unintended parameter value can result due to This Port Only reset. Parameter 0:457 [Purge Frequency] is reset to the default value when a Set Defaults for This Port Only is applied to port 10 or port 11.

Peripheral Set Defaults Operation Resets Host Product

The parameters for some
PowerFlex®
750-Series option modules reside on the main control board of the host product. Because of this scheme, performing a Set Defaults operation for one of these peripheral devices resets the host product. The peripherals that behave in this way are listed in this table.
Peripheral
Cat. No.
11-Series I/O option modules
20-750-1132C-2R
20-750-1133C-1R2T
20-750-1132D-2R
22-Series I/O option modules
20-750-2232C-2R
20-750-2233C-1R2T
20-750-2232D-2R
Single incremental encoder option module
20-750-ENC-1
Dual incremental encoder option module
20-750-DENC-1
Provide Feedback
Have questions or feedback about this documentation? Please submit your feedback here.