Module-defined Data Types (1756-DMA50)

Module-defined data type names vary for each module depending on the Communication Format you choose when you create a module. The table below lists and describes the module-defined data types created for the 1756-DMA50 module according to the Communication Format chosen. It includes information for input (as indicated by an "I") and output (as indicated by an "O").
Module-defined Data Type: AB:DMA50_GENERIC:I:0
Comm Format: User-defined Control
Member Name
Bit in
Previous Word
Data Type
Default Display Style
Drive Parameter
Description
LogicStatus
DINT
Binary
155
Logic Status
Enabled
0*
BOOL
Decimal
155.0
Enabled
Running
1*
BOOL
Decimal
155.1
Running
CommandDir
2*
BOOL
Decimal
155.2
Command Dir
ActualDir
3*
BOOL
Decimal
155.3
Actual Dir
Accelerating
4
BOOL
Decimal
155.4
Accelerating
Decelerating
5
BOOL
Decimal
155.5
Decelerating
Jogging
6
BOOL
Decimal
155.6
Jogging
Faulted
7*
BOOL
Decimal
155.7
Faulted
Alarm
8*
BOOL
Decimal
155.8
Alarm
FlashMode
9*
BOOL
Decimal
155.9
Flash Mode
RunReady
10
BOOL
Decimal
155.10
Run Ready
AtLimit
11
BOOL
Decimal
155.11
At Limit
TachLossSw
12
BOOL
Decimal
155.12
Tach Loss Sw
AtZeroSpd
13
BOOL
Decimal
155.13
At Zero Spd
AtSetptSpd
14
BOOL
Decimal
155.14
At Setpt Spd
AtSetpt1
16
BOOL
Decimal
155.16
At Setpt 1
AboveSetpt2
17
BOOL
Decimal
155.17
Above Setpt2
MCEnAck
18
BOOL
Decimal
155.18
MC En Ack
MCCommis
19
BOOL
Decimal
155.19
MC Commis
SpdCommis
20
BOOL
Decimal
155.20
Spd Commis
TorqueMode
22
BOOL
Decimal
155.22
Torque Mode
SpeedMode
23
BOOL
Decimal
155.23
Speed Mode
PositionMode
24
BOOL
Decimal
155.24
PositionMode
StartActive
25
BOOL
Decimal
155.25
Start Active
CommandRun
26
BOOL
Decimal
155.26
Command Run
UserDefinedRealData
REAL[12]
Float
User-defined
User-defined Real Data
UserDefinedIntegerData
DINT[3]
Decimal
User-defined
User-defined Integer Data
* Location of these bits are fixed for DPI.
Module-defined Data Type: AB:DMA50_GENERIC:O:0
Comm Format: User-defined Control
Member Name
Bit in
Previous Word
Data Type
Default Display Style
Drive Parameter
Description
LogicCommand
DINT
Binary
151
Logic Command
SpdRampDsbl
0
BOOL
Decimal
151.0
SpdRamp Dsbl
SpdSCrvEn
1
BOOL
Decimal
151.1
Spd S Crv En
TachLossRst
2
BOOL
Decimal
151.2
TachLoss Rst
TimeAxisEn
3
BOOL
Decimal
151.3
Time Axis En
MCAtuneEn
4
BOOL
Decimal
151.4
MC Atune En
MtrInertEn
8
BOOL
Decimal
151.8
Mtr Inert En
SysInertEn
9
BOOL
Decimal
151.9
Sys Inert En
InertiaComp
10
BOOL
Decimal
151.10
Inertia Comp
FrictComp
11
BOOL
Decimal
151.11
Frict Comp
ProcsTrimEn
12
BOOL
Decimal
151.12
ProcsTrim En
NormalStop
16
BOOL
Decimal
* Logic Parser
Normal Stop
Start
17
BOOL
Decimal
* Logic Parser
Start
Jog1
18
BOOL
Decimal
* Logic Parser
Jog 1
ClearFault
19
BOOL
Decimal
* Logic Parser
Clear Fault
UnipolFwd
20
BOOL
Decimal
* Logic Parser
Unipol Fwd
UnipolRev
21
BOOL
Decimal
* Logic Parser
Unipol Rev
Jog2
23
BOOL
Decimal
* Logic Parser
Jog 2
CurrLimStop
24
BOOL
Decimal
* Logic Parser
CurrLim Stop
CoastStop
25
BOOL
Decimal
* Logic Parser
Coast Stop
PositionEn
26
BOOL
Decimal
* Logic Parser
Position En
UserDefinedRealData
REAL[12]
Float
User-defined
User-defined Real Data
UserDefinedIntegerData
DINT[3]
Decimal
User-defined
User-defined Integer Data
* The output of the Logic Parser is mapped to parameter 152, bits 16-31.
Module-defined Data Type: AB: DMA50_CUSTOMUSER_DEFINED:I:0
Comm Format: Custom User-defined Control
Member Name
Data Type
Default Display Style
Drive Parameter
Description
LogicStatus
DINT
Binary
155
Logic Status
UserDefinedRealData
REAL[8]
Float
User-defined
User-defined Real Data
UserDefinedIntegerData
DINT[7]
Decimal
User-defined
User-defined Integer Data
Module-defined Data Type: AB: DMA50_CUSTOMUSER_DEFINED:O:0
Comm Format: Custom User-defined Control
Member Name
Data Type
Default Display Style
Drive Parameter
Description
LogicCommand
DINT
Binary
151
Logic Command
UserDefinedRealData
REAL[8]
Float
User-defined
User-defined Real Data
UserDefinedIntegerData
DINT[7]
Decimal
User-defined
User-defined Integer Data