Module-defined Data Types (1336T via ControlNet Adapter)

The tables below list and describe the Input and Output module-defined data types for this module.
TIP:
These data types apply to the 1336T drive when you are accessing it via the ControlNet adapter board. If you are accessing the 1336T drive via the 1203-CN1 communication module, the data types are different.
Module-defined Data Type: AB:1336T_AC_DRIVE:I:0
Comm Format: Data
Member Name
Data Type
Default Display Style
Parameter Description
Drive Parameter
DriveDataOut0*
INT
Decimal
CntlNet Out 0
351 <- User-defined
DriveDataOut1*
INT
Decimal
CntlNet Out 1
352 <- User-defined
DriveDataOut2*
INT
Decimal
CntlNet Out 2
353 <- User-defined
DriveDataOut3*
INT
Decimal
CntlNet Out 3
354 <- User-defined
DriveDataOut4*
INT
Decimal
CntlNet Out 4
355 <- User-defined
DriveDataOut5*
INT
Decimal
CntlNet Out 5
356 <- User-defined
DriveDataOut6*
INT
Decimal
CntlNet Out 6
357 <- User-defined
DriveDataOut7*
INT
Decimal
CntlNet Out 7
358 <- User-defined
* The actual meaning of the drive output value is determined by linking the CntlNet Out X parameter to the desired source parameter in the drive, using DriveExecutive.
Module-defined Data Type: AB:1336T_AC_DRIVE:O:0
Comm Format: Data
Member Name
Data Type
Default Display Style
Description
Drive Parameter
DriveDataIn0*
INT
Decimal
CntlNet In 0
322 <- User-defined
DriveDataIn1*
INT
Decimal
CntlNet In 1
323 <- User-defined
DriveDataIn2*
INT
Decimal
CntlNet In 2
324 <- User-defined
DriveDataIn3*
INT
Decimal
CntlNet In 3
325 <- User-defined
DriveDataIn4*
INT
Decimal
CntlNet In 4
326 <- User-defined
DriveDataIn5*
INT
Decimal
CntlNet In 5
327 <- User-defined
DriveDataIn6*
INT
Decimal
CntlNet In 6
328 <- User-defined
DriveDataIn7*
INT
Decimal
CntlNet In 7
329 <- User-defined
* The actual meaning of the drive input value is determined by linking the CntlNet In X parameter to the desired source parameter in the drive, using DriveExecutive.