Module Data Types - 1794-IF8I/A

The table below lists and describes module-defined data types for the 1794-IF8I analog input module. It includes information for input (as indicated by an I) and configuration (as indicated by a C).
Module-defined Data Type: AB:1794_IF8I:I:0
Member Name
Type
Default
Display Style
Description
Fault
DINT
Binary
Fault - Used for Input Data Validation
0 = Valid Data
1 = Invalid Data - if the connection to the module has been lost, or if the module has a severe hardware fault, the lower 8 members are set to 1.
Ch0Data
INT
Binary
Input data for channel 0.
Ch1Data
INT
Binary
Input data for channel 1.
Ch2Data
INT
Binary
Input data for channel 2.
Ch3Data
INT
Binary
Input data for channel 3.
Ch4Data
INT
Binary
Input data for channel 4.
Ch5Data
INT
Binary
Input data for channel 5.
Ch6Data
INT
Binary
Input data for channel 6.
Ch7Data
INT
Binary
Input data for channel 7.
 CalibrationDone
 BIT
Set to 1 after calibration cycle completed.
 CalibrationBad
 BIT
Set to 1 if channel calibration coefficients cannot be saved or read properly.
 CalibrationMode
 BIT
Set to 1 when calibration mode is selected.
 GeneralFault
 BIT
 FieldPowerOff
 BIT
Set to 1 when the 24V field power fails. The module status indicator flashes when set.
 PowerUp
 BIT
This member is set when the configuration word is all zeros due to reset or a cleared configuration word. The module status indicator flashes when set.
Ch0Underrange
Ch1Underrange
Ch2Underrange
Ch3Underrange
Ch4Underrange
Ch5Underrange
Ch6Underrange
Ch7Underrange
 BIT
Each member is set when its corresponding input channel is below a preset limit defined by the selected configuration.
Ch0Overrange
Ch1Overrange
Ch2Overrange
Ch3Overrange
Ch4Overrange
Ch5Overrange
Ch6Overrange
Ch7Overrange
 BIT
Each member is set when its corresponding input channel is above a preset limit defined by the selected configuration.
Module-defined Data Type: AB:1794_IF8I:C:0
Member Name
Type
Default
Display Style
Description
Ch0RangeType_0
Ch0RangeType_1
Ch1RangeType_2
Ch1RangeType_3
Ch2RangeType_4
Ch2RangeType_5
Ch3RangeType_6
Ch3RangeType_7
Ch4RangeType_8
Ch4RangeType_9
Ch5RangeType_10
Ch5RangeType_11
Ch6RangeType_12
Ch6RangeType_13
Ch7RangeType_14
Ch7RangeType_15
BIT
Ch0Rate_0
Ch0Rate_1
Ch1Rate_2
Ch1Rate_3
Ch2Rate_4
Ch2Rate_5
Ch3Rate_6
Ch3Rate_7
Ch4Rate_8
Ch4Rate_9
Ch5Rate_10
Ch5Rate_11
Ch6Rate_12
Ch6Rate_13
Ch7Rate_14
Ch7Rate_15
BIT
Ch0Calibrate
Ch1Calibrate
Ch2Calibrate
Ch3Calibrate
Ch4Calibrate
Ch5Calibrate
Ch6Calibrate
Ch7Calibrate
 BIT
GainOffsetCalibrate
 BIT
Holds the High or Low Reference settings you selected on the Input Configuration tab from the Module Properties dialog box.
CalibrationClock
 BIT
If selected, calibration mode starts and calibration settings for the selected channels are accepted.
If clear, the accepted current calibration coefficients are stored to selected channels, applied and calibration mode is exited.
QuickCalibration
 BIT
If set to 1, calibration coefficient is stored to all related configurations for selected channels.
DefaultCalibration
 BIT