Motion Instruction Compatibility

The following table correlates the motion instructions with the compatible control modes. The compatibility with integrated motion is based on the Axis Configuration and feedback type settings. The motion instructions tables are divided by type.
Use the following key to interpret the column entries:
Symbol
Meaning
x
Control mode is compatible.
#
MSO and MDS execution initiate mutually exclusive modes of operation and execution is conditional on mode.
*
Axis may be used as a master axis reference only for this instruction.
c
Axis may conditionally use Motion Planner instructions if enabled with an MSO instruction; otherwise, there is an error.
S
Supported in Controller Loop Back Configuration of Axis Test Mode.
Instruction provides an ideal response, executes successfully, and sequences as expected. Support includes some error conditions. Corner-case scenarios that might not be possible for axis with Axis Test Mode enabled setting must be modified to allow successful sequencing of the program.
N
Not Supported in Controller Loop Back Configuration of Axis Test Mode.
Instructions that have specific error codes or do not complete.
Instructions that do not generate errors, complete, but do not perform the instruction function.
Instruction logic in the user program for axis with Axis Test Mode enabled setting must be modified as Axis to allow sequencing of the program.
Shaded areas denote that Multi-Axis Coordination Motion is designed and tested for position mode operation but not restricted to that axis configuration.
Category
Motion Instruction Name
Abbr.
Feedback Only
Freq.Cntrl
No Feedback
Pos. Loop
Vel. Loop
Feedback
Vel. Loop
No Feedback
Torque Loop
Axis Test Mode Support
(Test Mode Configuration)
State Control
Motion Direct Drive On
MDO
Motion Direct Drive Off
MDF
Motion Servo On
MSO
#S
xS
#S
#S
#S
Controller Loop Back: V35
Motion Servo Off
MSF
xS
xS
xS
xS
xS
Controller Loop Back: V35
Motion Axis Fault Reset
MAFR
xS
xS
xS
xS
xS
xS
Controller Loop Back: V36
Motion Axis Shutdown
MASD
xS
xS
xS
xS
xS
xS
Controller Loop Back: V35
Motion Axis Shutdown Reset
MASR
xS
xS
xS
xS
xS
xS
Controller Loop Back: V35
Motion Drive Start
MDS
#
#
#
#
Event Control
Motion Arm Watch Position
MAW
xN
xS
xN
xN
Controller Loop Back: V35
Motion Disarm Watch Position
MDW
xN
xS
xN
xN
Controller Loop Back: V35
Motion Arm Registration
MAR
xN
xN
xN
xN
N-Controller Loop Back: V35
(Instruction does not complete because Events are not supported.)
Motion Disarm Registration
MDR
xN
xN
xN
xN
N-Controller Loop Back: V35
(Instruction does not complete because Events are not supported.)
Motion Arm Output Cam
MAOC
xN
xS
xN
xN
Controller Loop Back: V35
Motion Disarm Output Cam
MDOC
xN
xS
xN
xN
Controller Loop Back: V35
Move Control
Motion Redefine Position
MRP
xS
cS
xS
cS
cS
cS
Controller Loop Back: V35
Motion Axis Home
MAH
xS
xS
cS
cS
Controller Loop Back: V35 (Instruction only supports Immediate homing.)
Motion Axis Jog
MAJ
cN
xS
cN
cN
Controller Loop Back: V35
Motion Axis Move
MAM
cN
xS
cN
cN
Controller Loop Back: V35
Motion Change Dynamics
MCD
cN
xS
cN
cN
Controller Loop Back: V35
Motion Axis Stop
MAS
xS
xS
xS
xS
xS
xS
Controller Loop Back: V35
Motion Axis Gear
MAG
*N
cN
xS
cN
cN
*N
Controller Loop Back: V35
Motion Master Driven Axis Control
MDAC
*N
cN
xS
cN
cN
*N
Controller Loop Back: V35
Motion Axis Position Cam
MAPC
N
N
xS
cN
cN
*N
Controller Loop Back: V35
Motion Axis Time Cam
MATC
cN
xS
cN
cN
Controller Loop Back: V35
Multi-Axis Coordinate
Motion Coordinated Linear Move
MCLM
cN
xS
cN
cN
Controller Loop Back: V35
Motion Coordinated Circular Move
MCCM
cN
S
cN
cN
Controller Loop Back: V35
Motion Coordinated Stop
MCS
xS
xS
xS
xS
xS
xS
Controller Loop Back: V35
Motion Coordinated Shutdown
MCSD
xS
xS
xS
xS
xS
xS
Controller Loop Back: V35
Motion Coordinated Shutdown Reset
MCSR
x
xS
xS
xS
xS
xS
Controller Loop Back: V35
Motion Coordinated Change Dynamics
MCCD
xN
xS
xN
xN
Controller Loop Back: V35
Motion Coordinated Transform
MCT
xN
xS
xN
xN
Controller Loop Back: V35
Motion Calculate Target Position
MCTP
xS
xS
xS
xS
xS
xS
Controller Loop Back: V35
Motion Master Driven Coordinated Control
MDCC
*N
xN
xS
xN
*N
*N
Controller Loop Back: V35
Motion Configuration
Motion Run Axis Tuning
MRAT
xN
xN
xN
Controller Loop Back: V35
(Instruction returns error as Loopback model doees not support Tuning.)
Motion Apply Axis Tuning
MAAT
xN
Controller Loop Back: V35
(Instruction returns error as Loopback model doees not support Tuning.)
Motion Run Hookup Diagnostic
MRHD
xN
xN
xN
xN
xN
xN
Controller Loop Back: V35
(Instruction returns error as Loop Back model does not support Diagnostic tests.)
Motion Apply Hookup Diagnostic
MAHD
xN
Controller Loop Back: V35
(Instruction returns error as Loop Back model does not support Diagnostic tests.)
Group Control
Motion Group Strobe Position
MGSP
xN
xN
xS
xN
xN
xN
Controller Loop Back: V35
Motion Group Shutdown
MGSD
xS
xS
xS
xS
xS
xS
Controller Loop Back: V35
Motion Group Shutdown Reset
MGSR
xS
xS
x
xS
xS
xS
Controller Loop Back: V35
Motion Group Stop
MGS
xS
xS
x
xS
xS
xS
Controller Loop Back: V35
Provide Feedback