Attribute Units
    Attribute Units define the unit nomenclature found in the Semantics of Values column for many of the Motion Control Axis Attributes. In general, attribute values are specified in units that are relevant to motion control engineers.
Attribute Unit Cross-referencing
| Attribute Unit | Applicable Units | Semantics of Values | 
|---|---|---|
| Position Unit | User String | User-defined unit of measure of motion displacement, for example, meters, feet, inches, millimeters, revolutions, or degrees. | 
| Velocity Units | Position Units/Sec | For example, Revs/Sec, Inches/Sec | 
| Accel Units | Position Units/Sec 2 | For example, Revs/Sec 2 , Inches/Sec 2 | 
| Jerk Units | Position Units/Sec 3 | For example, Revs/Sec 3, Inches/Sec 3 | 
| % Device Rated |  % | Defined as the percentage of the continuous rating of the device with 100% implying operation at the continuous rated specification for the device. This unit can be applied to attributes related to speed, torque, force, current, voltage, and power. Applicable devices can be a motor, inverter, converter, or a bus regulator. This unit can be used independent of whether the attribute value represents an instantaneous level or a time-averaged level; the appropriate unit for the device rating is implied. As with all attributes that are in units of %, an attribute value of 100 means 100%. | 
| Power Units | Kw | Kilowatts | 
| Inertia Units | Kg-m 2 | Kilogram-Meter 2 | 
| Mass Units | Kg | Kilogram | 
| Loop Bandwidth Units | Hz | Hertz | 
| Filter Frequency Units | Hz | Hertz | 
| Counts | Fundamental control unit for distance. For example, feedback counts or planner counts. | 