Feature tokens

Each
FactoryTalk® Optix
runtime entitlement corresponds to a "token container", within which designers can select and activate the functions necessary to develop an application. Feature tokens function as a unit of currency and accumulate as you configure more features in an application. Each function has a token value associated with it, and some functions can be used for free without having a token cost. You can upgrade your entitlement at any time to allow application expansion, and there is an unlimited option that gives you maximum flexibility and expansion.
The selection of components and functions to be activated and used in the project is done at the time of programming with
FactoryTalk® Optix Studio
.
FactoryTalk® Optix
runtime verifies that the total amount of tokens associated with all features activated is within the token limit of your purchased entitlement.
Examples of features that affect the sizing of your application include the following:
  • Controller connections
  • Multiple web clients
  • Alarming
  • Recipe
  • PDF reports
  • Data logging
  • Database connectivity
  • OPC UA connectivity
FactoryTalk Optix feature token packages
Station Runtime—Lite
Station Runtime—Standard
Station Runtime—Pro
Package size
XS
S
M
L
XL
Unlimited
Feature tokens included
5
8
11
15
21
Unlimited

Supported feature tokens

The tables in this section describe the features available with
FactoryTalk® Optix
and the number of feature tokens that are required to use them.
Basic HMI feature tokens
Feature
No. of tokens
Core framework, graphics, data controls, charts, user management
Free
Native HMI graphic rendering (1 client)
1
HTML5 HMI graphic rendering (1 web client)
1
HTML5 HMI graphic rendering (up to 3 web clients)
2
HTML5 HMI graphic rendering (up to 5 web clients)
3
HTML5 HMI graphic rendering (up to 10 web clients)
5
HTML5 HMI graphic rendering (up to 20 web clients)
7
Alarming
1
Event Logger (includes Alarm History)
1
Runtime retentivity
1
Data logger
1
Recipes
1
Basic PDF reporting
1
Audit signature
Preview
Active directory authentication
1
OPC UA feature tokens
Feature
No. of tokens
OPC UA client:
FactoryTalk® Optix
is a client to another OPC UA server
OPC UA Client – (connected to 1 server)
1
OPC UA Client – (connected to multiple servers)
2
OPC UA server:
FactoryTalk® Optix
is a server to other OPC UA clients
OPC UA Server – (1 connected client)
1
OPC UA Server – (up to 3 connected clients)
2
OPC UA Server – (up to 5 connected clients)
3
OPC UA Server – (up to 10 connected clients)
5
OPC UA Server – (up to 20 connected clients)
7
Database feature tokens
Feature
No. of tokens
Database – Embedded (single database)
1
Database – ODBC (1 database connection)
1
Database – ODBC (up to 3 database connections)
2
Database – ODBC (up to 5 database connections)
3
MQTT connectivity
Feature
No. of tokens
MQTT broker
Preview
MQTT subscriber
Preview
MQTT publisher
Preview
Controller communications features
Feature
No. of tokens
For 
Logix 5000®
controllers
1 controller connection
Free
Multiple controller connections
1
For non-
Allen-Bradley®
controllers
1 controller connection
1
Multiple controller connections
2
Runtime tag upload from controller (Siemens S7, Beckhoff)
1
Supported communication drivers include:
  • Allen-Bradley®
    EtherNet/IP
    driver
  • Microcontroller driver
  • Modbus driver
  • Mitsubishi MELSEC FX3U
  • Omron
    EtherNet/IP
    driver
  • Omron FINS driver
  • Siemens S7 TCP driver
  • Siemens S7 TIA PROFINET driver
Provide Feedback
Have questions or feedback about this documentation? Please submit your feedback here.