Degrees (DEG)

When enabled, the DEG instruction converts the Source (in radians) to degrees and stores the result in the Destination.
The DEG instruction uses this algorithm:
Source*180/pi = Source*57.29578
Available Languages
Ladder Diagram
Ladder Diagram_Degrees (DEG)_v1
Structured Text
This instruction is not available in structured text. However, in the Structured Text Editor you can use DEG as an operator in an expression to compute the same result. Refer to Structured Text syntax for more information on the syntax of expressions and assignments within structured text.
Operands
IMPORTANT: Unexpected operation may occur if:
  • Output tag operands are overwritten
  • Members of a structure operand are overwritten
  • Except when specified, structure operands are shared by multiple instructions.
There are data conversion rules for mixing numeric data types within an instruction. See Data conversions.
Ladder Diagram
Operand
Data Type
Format
Description
Source
SINT
INT
DINT
LINT
USINT
UINT
UDINT
ULINT
REAL
LREAL
Immediate
tag
Value to convert to degrees
Destination
SINT
INT
DINT
LINT
USINT
UINT
UDINT
ULINT
REAL
LREAL
tag
Tag to store the result
Affects Math Status Flags
Conditional. See Math status flags.
Major/Minor Faults
None
specific to this instruction. See Index through arrays for array-indexing faults.
Execution
Ladder Diagram
Condition/State
Action taken
Prescan
N/A
Rung-condition-in is false
Set Rung-condition-out to Rung-condition-in.
Rung-condition-in is true
Set Rung-condition-out to Rung-condition-in.
Dest = degree value of the Source.
Postscan
N/A
Examples
Ladder Diagram
FTStudio-DEG-LD-EX-V1
Structured Text
REAL_dest := DEG(REAL_src);